Optimization of Artificial Siderophores as 68Ga-Complexed PET Tracers for in Vivo Imaging of Bacterial Infections

Download statistics - Document (COUNTER):

Peukert, C.; Langer, L.N.B.; Wegener, S.M.; Tutov, A.; Bankstahl, J.P. et al.: Optimization of Artificial Siderophores as 68Ga-Complexed PET Tracers for in Vivo Imaging of Bacterial Infections. In: Journal of Medicinal Chemistry (formerly: Journal of Medicinal and Pharmaceutical Chemistry) 64 (2021), Nr. 16, S. 12359-12378. DOI: https://doi.org/10.1021/acs.jmedchem.1c01054

Repository version

To cite the version in the repository, please use this identifier: https://doi.org/10.15488/16461

Selected time period:

year: 
month: 

Sum total of downloads: 10




Thumbnail
Abstract: 
The diagnosis of bacterial infections at deep body sites benefits from noninvasive imaging of molecular probes that can be traced by positron emission tomography (PET). We specifically labeled bacteria by targeting their iron transport system with artificial siderophores. The cyclen-based probes contain different binding sites for iron and the PET nuclide gallium-68. A panel of 11 siderophores with different iron coordination numbers and geometries was synthesized in up to 8 steps, and candidates with the best siderophore potential were selected by a growth recovery assay. The probes [68Ga]7 and [68Ga]15 were found to be suitable for PET imaging based on their radiochemical yield, radiochemical purity, and complex stability in vitro and in vivo. Both showed significant uptake in mice infected with Escherichia coli and were able to discern infection from lipopolysaccharide-triggered, sterile inflammation. The study qualifies cyclen-based artificial siderophores as readily accessible scaffolds for the in vivo imaging of bacteria.
License of this version: CC BY-NC-ND 4.0 Unported
Document Type: Article
Publishing status: publishedVersion
Issue Date: 2021
Appears in Collections:Forschungszentren

distribution of downloads over the selected time period:

downloads by country:

pos. country downloads
total perc.
1 image of flag of Germany Germany 6 60.00%
2 image of flag of United States United States 2 20.00%
3 image of flag of India India 1 10.00%
4 image of flag of Indonesia Indonesia 1 10.00%

Further download figures and rankings:


Hinweis

Zur Erhebung der Downloadstatistiken kommen entsprechend dem „COUNTER Code of Practice for e-Resources“ international anerkannte Regeln und Normen zur Anwendung. COUNTER ist eine internationale Non-Profit-Organisation, in der Bibliotheksverbände, Datenbankanbieter und Verlage gemeinsam an Standards zur Erhebung, Speicherung und Verarbeitung von Nutzungsdaten elektronischer Ressourcen arbeiten, welche so Objektivität und Vergleichbarkeit gewährleisten sollen. Es werden hierbei ausschließlich Zugriffe auf die entsprechenden Volltexte ausgewertet, keine Aufrufe der Website an sich.

Search the repository


Browse