Show simple item record

dc.identifier.uri http://dx.doi.org/10.15488/4903
dc.identifier.uri https://www.repo.uni-hannover.de/handle/123456789/4946
dc.contributor.author Schueling, Torsten
dc.contributor.author Eilers, Alina
dc.contributor.author Scheper, Thomas
dc.contributor.author Walter, Johanna
dc.date.accessioned 2019-05-29T10:48:51Z
dc.date.available 2019-05-29T10:48:51Z
dc.date.issued 2018
dc.identifier.citation Schueling, T.; Eilers, A.; Scheper, T.; Walter, J.: Aptamer-based lateral flow assays. In: AIMS Bioengineering 5 (2018), Nr. 2, S. 78-102. DOI: https://doi.org/10.3934/bioeng.2018.2.78
dc.description.abstract Lateral flow assays as point-of-care devices have attracted interest due to their advantages including low costs, easy operation by non-specialized users and low analyte volumes needed. These advantages make lateral flow assays to superior tools for the on-site detection of analytes with qualitative or semi-quantitative results within minutes. Aptamers are single-stranded nucleic acid oligomers with distinct conformational shapes that can bind their corresponding targets via molecular recognition. Due to their specific properties like an efficient chemical synthesis, a longer shelf life and easy introduction of modifications aptamers seem to be ideal biological recognition elements. Moreover, they enable the design of intelligent detection schemes not available with antibodies. This review focuses on lateral flow assays utilizing aptamers as an element for molecular recognition. In the first part of the review, a brief overview on lateral flow assays and aptamers, regarding their generation and properties, will be given. In the second part, a review of recently published literature on this topic will demonstrate the broad spectrum of possible applications and analytes, detectable with aptamer-based lateral flow assays. eng
dc.language.iso eng
dc.publisher Springield : AIMS Press
dc.relation.ispartofseries AIMS Bioengineering 5 (2018), Nr. 2
dc.rights CC BY 4.0 Unported
dc.rights.uri https://creativecommons.org/licenses/by/4.0/
dc.subject aptamers eng
dc.subject lateral flow assay eng
dc.subject biosensor eng
dc.subject aptasensor eng
dc.subject sandwich assay eng
dc.subject competitive assay eng
dc.subject.ddc 600 | Technik ger
dc.subject.ddc 540 | Chemie ger
dc.title Aptamer-based lateral flow assays eng
dc.type Article
dc.type Text
dc.relation.essn 2375-1495
dc.relation.issn 2375-1487
dc.relation.doi https://doi.org/10.3934/bioeng.2018.2.78
dc.bibliographicCitation.issue 2
dc.bibliographicCitation.volume 5
dc.bibliographicCitation.firstPage 78
dc.bibliographicCitation.lastPage 102
dc.description.version publishedVersion
tib.accessRights frei zug�nglich


Files in this item

This item appears in the following Collection(s):

Show simple item record

 

Search the repository


Browse

My Account

Usage Statistics