Development of an enhanced analytical method utilizing pepper matrix as an analyte protectant for sensitive GC-MS/MS detection of dimethipin in animal-based food products

Zur Kurzanzeige

dc.identifier.uri http://dx.doi.org/10.15488/16935
dc.identifier.uri https://www.repo.uni-hannover.de/handle/123456789/17062
dc.contributor.author Shim, Jae-Han
dc.contributor.author Rahman, Md. Musfiqur
dc.contributor.author Esatbeyoglu, Tuba
dc.contributor.author Oz, Fatih
dc.contributor.author Abd El-Aty, A.M.
dc.date.accessioned 2024-04-08T08:18:07Z
dc.date.available 2024-04-08T08:18:07Z
dc.date.issued 2023
dc.identifier.citation Shim, J.-H.; Rahman, M.M.; Esatbeyoglu, T.; Oz, F.; Abd El-Aty, A.M.: Development of an enhanced analytical method utilizing pepper matrix as an analyte protectant for sensitive GC-MS/MS detection of dimethipin in animal-based food products. In: PLoS ONE 18 (2023), Nr. 12, e0295968. DOI: https://doi.org/10.1371/journal.pone.0295968
dc.description.abstract Herein, an analytical method using gas chromatography-tandem mass spectrometry (GC- MS/MS) was devised to detect the presence of the troublesome pesticide dimethipin in various animal-based food products, including chicken, pork, beef, eggs, and milk. The injection port was primed with a matrix derived from pepper leaves that acts as an analyte protectant (AP) to safeguard the target compound from thermal degradation during gas chromatography. The presence of AP resulted in a remarkable limit of quantification of 0.005 mg/kg for dimethipin in five matrices. Three different versions (original, EN, and AOAC) of the QuEChERS (Quick, Easy, Cheap, Effective, Rugged, and Safe) method were compared for dimethipin extraction, with a double-layer solid-phase extraction (SPE) cartridge utilized for matrix purification. A seven-point external calibration curve was established for dimethipin in the five matrices, demonstrating excellent linearity with determination coefficients (R2) ≥ 0.998. The developed quantitative method was validated by fortifying each matrix with three different concentrations of standard dimethipin, and the average recovery fell within the acceptable range outlined in the CODEX guidelines (ranging from 88.8% to 110.0%), with a relative standard deviation (RSD) of ≤ 11.97%. This method effectively addresses the challenge of analyzing dimethipin and can therefore be used as a routine monitoring tool for dimethipin across various matrices. eng
dc.language.iso eng
dc.publisher San Francisco, California, US : PLOS
dc.relation.ispartofseries PLoS ONE 18 (2023), Nr. 12
dc.rights CC BY 4.0 Unported
dc.rights.uri https://creativecommons.org/licenses/by/4.0
dc.subject Animals eng
dc.subject Cattle eng
dc.subject Eggs eng
dc.subject Gas Chromatography-Mass Spectrometry eng
dc.subject Milk eng
dc.subject.ddc 500 | Naturwissenschaften
dc.subject.ddc 610 | Medizin, Gesundheit
dc.title Development of an enhanced analytical method utilizing pepper matrix as an analyte protectant for sensitive GC-MS/MS detection of dimethipin in animal-based food products eng
dc.type Article
dc.type Text
dc.relation.essn 1932-6203
dc.relation.doi https://doi.org/10.1371/journal.pone.0295968
dc.bibliographicCitation.issue 12
dc.bibliographicCitation.volume 18
dc.bibliographicCitation.firstPage e0295968
dc.description.version publishedVersion
tib.accessRights frei zug�nglich


Die Publikation erscheint in Sammlung(en):

Zur Kurzanzeige

 

Suche im Repositorium


Durchblättern

Mein Nutzer/innenkonto

Nutzungsstatistiken