Detection of 135Cs & 137Cs in environmental samples by AMS

Show simple item record

dc.identifier.uri http://dx.doi.org/10.15488/14753
dc.identifier.uri https://www.repo.uni-hannover.de/handle/123456789/14872
dc.contributor.author Wieser, Alexander
dc.contributor.author Lachner, Johannes
dc.contributor.author Martschini, Martin
dc.contributor.author Zok, Dorian
dc.contributor.author Priller, Alfred
dc.contributor.author Steier, Peter
dc.contributor.author Golser, Robin
dc.date.accessioned 2023-09-15T04:50:21Z
dc.date.available 2023-09-15T04:50:21Z
dc.date.issued 2023
dc.identifier.citation Wieser, A.; Lachner, J.; Martschini, M.; Zok, D.; Priller, A. et al.: Detection of 135Cs & 137Cs in environmental samples by AMS. In: Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms 538 (2023), S. 36-40. DOI: https://doi.org/10.1016/j.nimb.2023.02.013
dc.description.abstract The detection of low abundances of 135Cs in environmental samples is of significant interest in different fields of environmental sciences, especially in combination with its shorter-lived sister isotope 137Cs. The method of Ion–Laser InterAction Mass Spectrometry (ILIAMS) for barium separation at the Vienna Environmental Research Accelerator (VERA) was investigated and further improved for low abundance cesium detection. The difluorides BaF2- and CsF2- differ in their electron detachment energies and make isobar suppression with ILIAMS by more than 7 orders of magnitude possible. By this method, samples with ratios down to the order of 135,137Cs/133Cs ˜10-11 are measurable and the 135Cs/137Cs ratios of first environmental samples were determined by AMS. eng
dc.language.iso eng
dc.publisher Amsterdam [u.a.] : Elsevier
dc.relation.ispartofseries Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms 538 (2023)
dc.rights CC BY 4.0 Unported
dc.rights.uri https://creativecommons.org/licenses/by/4.0
dc.subject 135 Cs eng
dc.subject 137 Cs eng
dc.subject Accelerator mass spectrometry eng
dc.subject ILIAMS eng
dc.subject Ion cooler eng
dc.subject Laser photodetachment eng
dc.subject.ddc 530 | Physik
dc.title Detection of 135Cs & 137Cs in environmental samples by AMS eng
dc.type Article
dc.type Text
dc.relation.essn 1872-9584
dc.relation.issn 0168-583X
dc.relation.doi https://doi.org/10.1016/j.nimb.2023.02.013
dc.bibliographicCitation.volume 538
dc.bibliographicCitation.firstPage 36
dc.bibliographicCitation.lastPage 40
dc.description.version publishedVersion
tib.accessRights frei zug�nglich


Files in this item

This item appears in the following Collection(s):

Show simple item record

 

Search the repository


Browse

My Account

Usage Statistics