Mertes, F.; Kneip, N.; Heinke, R.; Kieck, T.; Studer, D. et al.: Ion implantation of 226Ra for a primary 222Rn emanation standard. In: Applied radiation and isotopes : a journal of nuclear and radiation techniques and their applications in the physical, chemical, biological, medical, earth, planetary, environmental and engineering science 181 (2022), 110093. DOI: https://doi.org/10.1016/j.apradiso.2021.110093
Zusammenfassung: | |
Laser resonance ionization at the RISIKO 30 kV mass separator has been used to produce isotopically and isobarically pure and well quantified 222Rn emanation standards. Based upon laser-spectroscopic preparation studies, ion implantation into aluminum and tungsten targets has been carried out, providing overall implantation efficiencies of 40% up to 60%. The absolute implanted activity of 226Ra was determined by the technique of defined solid-angle α-particle spectrometry, where excellent energy resolution was observed. The 222Rn emanation coefficient of the produced targets was studied using α-particle and γ-ray spectrometry, and yielded results between 0.23 and 0.34, with relative uncertainty on the order of 1%. No dependence exceeding a 1% change of the emanation on humidity could be identified in the range of 15 %rH to 75 %rH, whereas there were hints of a slight correlation between the emanation and temperature. Additionally, and as expected, the emanation coefficient was found to be dependent on the target material as well as the implanted dose. © 2021 | |
Lizenzbestimmungen: | CC BY 4.0 Unported |
Publikationstyp: | Article |
Publikationsstatus: | publishedVersion |
Erstveröffentlichung: | 2022 |
Die Publikation erscheint in Sammlung(en): | Forschungszentren |
Pos. | Land | Downloads | ||
---|---|---|---|---|
Anzahl | Proz. | |||
1 | ![]() |
Germany | 24 | 40,68% |
2 | ![]() |
United States | 14 | 23,73% |
3 | ![]() |
Russian Federation | 8 | 13,56% |
4 | ![]() |
China | 5 | 8,47% |
5 | ![]() |
Taiwan | 2 | 3,39% |
6 | ![]() |
Serbia | 2 | 3,39% |
7 | ![]() |
Netherlands | 2 | 3,39% |
8 | ![]() |
Japan | 1 | 1,69% |
9 | ![]() |
Europe | 1 | 1,69% |
Hinweis
Zur Erhebung der Downloadstatistiken kommen entsprechend dem „COUNTER Code of Practice for e-Resources“ international anerkannte Regeln und Normen zur Anwendung. COUNTER ist eine internationale Non-Profit-Organisation, in der Bibliotheksverbände, Datenbankanbieter und Verlage gemeinsam an Standards zur Erhebung, Speicherung und Verarbeitung von Nutzungsdaten elektronischer Ressourcen arbeiten, welche so Objektivität und Vergleichbarkeit gewährleisten sollen. Es werden hierbei ausschließlich Zugriffe auf die entsprechenden Volltexte ausgewertet, keine Aufrufe der Website an sich.